Client can choose the following avenues for material choice*
*The requested use of materials does not gaurentee compliance with the regulations
1 – 5 working days on average for single buildings
Express delivery available at additonal costs. Booking essential
PDF: Report, certificate, Form 2 and Form 4
Offering the lowest prices in the market with superior end
products and service






















Select the closest total gross building area of your single building project to receive an instant quote
Prices are Excluding VAT
T’s & C’s apply. Plans will need to be provided to verify final amount
Compliance by comparing to a reference building:
We model and set up all data accurately according to how the Architect has specified everything and then we take that model and simulate it to get monthly and hourly data specifying how much energy the building needs to keep it at a comfortable temperature.
We also model up a reference building which is set up with the minimum requirements (according to SANS 10400-XA) so that it is deemed-to-satisfy.
We can then compare the data of both the actual building and the reference building to see if the actual building performs better or worse than the reference building. If it performs better, then we can say that it complies with SANS 10400-XA as it performs better than the minimum requirements needed for compliance.
We use a 3D energy modelling program called Design Builder. Design Builder allows us to accurately model up a building with all the factors that affect the efficiency of a building and is suitable to calculate the energy requirements for all building types. Design Builder simulates the building’s energy performance which tells us how much energy the building requires to keep it at a comfortable temperature.
Design Builder is certified by Agreement South Africa for energy modelling of buildings and produces data after simulation which is suitable to compare data from an actual and reference building for compliance.
• Most cost-effective solution to achieve optimum efficiency
• Accurate data used when modeling (Site specific, weather data, HVAC, Shading and Construction methods)
• You have complete freedom of design because we will ensure that it works in the end by making other aspects of the building perform better to compensate for energy loss due to desired design
Once we have received the necessary drawings, the quote has been approved and we have been appointed to do the Rational Design Assessment, we can start with the assessment.
We guarantee going above and beyond for you, work delivered on time with the optimum energy efficiency results for your building as well as cost savings.